An overflowing tank wastes water and electricity; a pump that runs with no water burns out. A float switch or an automatic water level controller fixes both by switching the pump on and off at the right levels without anyone watching.
Quick answer: A pump float switch costs KSh 2,630 on Buy More Mall and a small float level switch for controllers and Arduino projects costs KSh 850. Tank level float switches and electrode probes for control panels are quoted on request. A float switch is the simplest automatic controller; an electronic controller with probes adds dry-run protection and indicator lights.





| Item | Use | Price |
|---|---|---|
| DAYLIFF FLOATSWITCH | Cable float switch for pumps and tanks | KSh 2,630 |
| Float level switch | Small float switch for controllers / Arduino | KSh 850 |
| Tank Level Float Switches & Electrodes | Float switches and electrodes for panels | Price on request |
| Tank Float Valves (Ball-Cock) 1/2" - 2" | Mechanical ball-cock float valve (no electricity) | Price on request |
| DAYLIFF DSD3/18 COMPLETE WITH FLOATSWITCH | Pump supplied with a float switch | KSh 43,750 |
| Ultrasonic distance sensor (HC-SR04) | Ultrasonic level sensor for electronic monitoring | KSh 300 |
Prices shown are regular prices on Buy More Mall. Many products are currently on offer, so open the product page to see today's price.
A cable float switch is a sealed plastic body with a small steel ball and a switch inside, hanging on its cable. When the water lifts the float, it tips over, the ball rolls and the switch changes over. When the water drops, the float hangs down and the switch changes back. The length of free cable between the float and its tie point sets the gap between the ON and OFF levels.
| Type | How it works | Best for |
|---|---|---|
| Mechanical ball-cock float valve | A floating ball closes the inlet valve | Filling a tank from mains by gravity, no power |
| Cable float switch | Float tips and switches the pump | Pump filling an overhead tank or emptying a sump |
| Electronic controller with probes | Steel electrodes sense water at set levels | Two tanks: protects the pump from running dry and stops the top tank overflowing |
| Ultrasonic / pressure sensor + controller | Measures the level continuously | Showing the level as a %, alarms, remote monitoring |
Most cable float switches have three wires: a common wire and two others. One combination closes when the float is down (use it for filling a tank: the pump runs while the water is low). The other closes when the float is up (use it for emptying a sump or septic chamber: the pump runs while the water is high). The colours differ between makes, so follow the diagram printed on the cable label or the leaflet, and insulate the unused wire.
Two-tank systems: when a pump lifts water from a ground tank to a roof tank, use two switches: one in the top tank (start when low, stop when full) and one in the ground tank (stop the pump when the ground tank is empty). An electronic probe controller does both in one box.
| Symptom | Check |
|---|---|
| Pump never starts | Wrong wire pair, burnt contacts, float tangled or stuck against the wall |
| Pump never stops | Float trapped up, wrong pair (fill vs empty), welded contacts |
| Pump starts and stops rapidly | Free cable too short; lengthen it for a wider ON/OFF gap |
| Works sometimes | Water inside a cracked float, loose terminal, corroded joint |
A family in Ngong pumped water from a 5,000 litre ground tank to a 1,000 litre roof tank by hand-switching the pump, and the roof tank overflowed most nights. A float switch in the roof tank (fill pair) and a second one in the ground tank for dry-run protection now start and stop the pump automatically. The overflow stopped and the electricity bill dropped.
For a monitor that shows the tank level on your phone, see the ultrasonic tank project in our ESP32 guide.
A pump float switch is KSh 2,630 on Buy More Mall; a small level float switch for controllers is KSh 850.
It senses the water level with a float or probes and switches the pump on when the tank is low and off when it is full.
Use the fill or empty pair from the switch diagram, in series with the pump live wire for small pumps, or through a contactor for bigger pumps.
Yes for three-phase pumps and for any pump that draws more current than the switch rating.
A float valve mechanically closes a water inlet; a float switch electrically starts and stops a pump.
Not sure which one fits? Send us your details on WhatsApp or through the product page and we will help you choose.